Plumbing Leak Detection System Product Selection Guide

Trying to decide which RDT water leak detection solution is the best fit for your application? Start with our application chart, or contact us today to discuss your needs with an application specialist!

Installation Valve Size Power Output Signal? Audible Alarm? Temperature Sensing? Sensor Type Model No.
New - Leak Detection for Plenum SpacesWater Mains – App-Based, Wireless Full-Facility Protection 1/2″, 3/4″, 1″, 1-1/4″ 120 VAC Push Notification to App Yes Yes Wireless RSC-900
New - Leak Detection for Plenum SpacesPlenum-Rated Kits – Water Heaters, Water Mains, HVAC Pans, Simple Alarms 1/2″, 3/4″, 1″, 1-1/4″ Step-down transformer Dry Contacts – NO/C/NC Yes No Wired MK6 Series
Water Mains – Localized Protection 3/4″, 1″, 1-1/4″, 1-1/2″, 2″, 2-1/2″, 3″, 4″ 120 VAC Dry Contacts – NO/C/NC Yes No Wired RS-080
Washing Machines Dual-Port 3/4″ 120 VAC Dry Contacts – NO/C/NC Yes No Wired RS-090
Hose-Fed Appliance – Dishwashers, Ice Makers, Beverage Dispensers, RO Systems, etc. 1/2″ to 3/8″ fittings 120 VAC or step-down transformer Dry Contacts – NO/C/NC Yes No Wired RS-092
Water Heaters, Water Tanks, etc. 1/2″, 3/4″, 1″, 1-1/4″ 120 VAC Dry Contacts – NO/C/NC Yes No Wired RS-094
Modified Water Heater Kits for Specific Applications – Low-Profile Tanks, Power Vent and Gas Flow Shut-Off 3/4″ 120 VAC Dry Contacts – NO/C/NC Yes No Wired RS-094-MKX
Sump Pumps, Clean Rooms, etc. No Valve 9V Battery No Yes No Wired RS-095
120 VAC Dry Contacts – NO/C/NC Yes No Wired RS-096
HVAC / Condensate Pans No Valve 120 VAC Dry Contacts – NO/C/NC Yes No Wired (elevated 1/2″) RS-097
Sump Pumps, Clean Rooms, etc. WITH CELLULAR NOTIFICATION No Valve 120 VAC with Battery Backup Dry Contacts – NO/C/NC Yes Yes Float Switch(es) SM4838

Choosing Between a Wired & Wireless Leak Protection Solution

Both the Wired and Wireless Systems operate in basically the same way. The general rule of thumb is, if your leak detection needs require sensing on multiple living levels (basement, first floor, second floor, etc.) – or if you need app-based sensor identification, remote valve control and system notification via your smart phone – then you would probably be better off using the RSC-900 wireless system. If you are looking to detect in a single location (one appliance, or one room), a wired option is likely a more cost-effective choice. You can always contact RDT to discuss your application. We are committed to getting you the best solution!

Accessories to Customize Your Solution

A wide range of accessories is available to customize your installation according to your specific requirements.

All of the wired sensing products listed above (except for the FM-095 simple alarm) support the optional Sensing Rope Accessory Kit, which is ideal for use with low tanks or for room perimeter and sub-floor leak detection requirements. The Sensing Rope wires directly into the Sensor openings on the FloodMaster terminal block. Sold separately. For wired system, order Starter Kit RSA-175-810.

All of the wired sensing products listed above (except for the FM-095 simple alarm) can also provide external event notification via the Auto Dialer (RSA-600-003). The Auto Dialer wires directly into the Normal Open contacts on the FloodMaster terminal block. Accessories sold separately.